Researchers have developed a low-cost microscopy system that produces detailed histology-like images and quantitative molecular information from fresh, unprocessed tissue, without conventional sectioning or staining. Reported in BME Frontiers, the technique could enable faster pathological assessment during surgery while preserving tissue for subsequent diagnostic testing.
Conventional histopathology requires tissue fixation, sectioning, and staining, with results often taking hours or days. Frozen-section analysis provides faster results but introduces artifacts that can affect interpretation. Now, researchers at the Georgia Institute of Technology, Emory University, and St. Jude Children's Research Hospital have developed a deep-ultraviolet (UV) microscope that uses light-emitting diodes to image intact tissue.
The system measures how tissue absorbs UV light at two wavelengths, 255 and 280 nm, revealing the distribution of nucleic acids and proteins. It also measures natural fluorescence from tryptophan, an amino acid found in proteins.
Using these signals, the researchers generated quantitative maps of molecular composition alongside images resembling conventional hematoxylin and eosin (H&E)-stained sections. Unlike some virtual staining approaches, the technique uses a straightforward mathematical transformation rather than artificial intelligence, preserving the structural information captured by the microscope.
The researchers demonstrated the system using fresh mouse brain and kidney tissue and human brain tumor specimens. In kidney samples, the images clearly resolved structures including glomeruli. In human glioma samples, they revealed densely packed cell nuclei and differences in molecular composition compared with noncancerous brain tissue.
Tumor regions showed greater nuclear density and nucleic acid content, while tryptophan fluorescence efficiency was more than 50 percent lower than in healthy human brain tissue.
The microscope achieved approximately 0.5-µm lateral resolution. Imaging a 10 × 10-mm tissue area took approximately three minutes per wavelength.
For pathology laboratories, the ability to examine fresh tissue without preparing slides could support faster surgical decision-making and reduce dependence on conventional processing. However, the findings represent an early technical demonstration involving limited tissue types and two human tumor specimens. Clinical studies are needed to establish diagnostic accuracy, reproducibility, and performance across different diseases.